The pumping –in tests are carried out to determine the field permeability.
The two tests that fall in this category are :
This test is applicable for coarse-grained soils.
for this case k = Q / ( 5.5 rH), where, r = internal radius pipe, Q = inflow rate.
Fig.1.22 Constant Head test