Procedure:
A. Common Base configuration
- For the input characteristics of common base configuration, set-up the ckt of fig 4.1. Set VEE around 5-6 V and do not change it during the experiment (why?). Now vary VEB with the potentiometer and record IE keeping VCB at zero volt (Fig.3.2). Observations may be recorded up to a maximum of 30mA emitter current. Repeat the observations (for four sets) for various values of V CB from 0 to 10 V.
- For output characteristics follow the ckt of fig 4.1. Set VEE around 5-6 V and do not change it during the experiment. Set IE =0 with the pot and record the IC as a function of VCB (from 0-10V). Record at least four sets of O/p curve by varying IE from 0-20mA. (Fig. 3.3)
- Plot all the curves. Plot the load line. Find input and output resistances and current gain
.