Module 2: Defect Chemistry and Defect Equilibria
  Examples of Intrinsic Electronic and Ionic Defect Concentrations
 


2.19 Examples

2.19.1 Intrinsic electronic and ionic defect concentrations  in MgO 

Consider that a material like MgO usually has Schottky defects with enthalpy of formation (ΔHF)) of about 7.7 eV. Its band gap is about 7.65 eV which decreases at a rate of 1 meV per K as MgO is heated.

The question is that in case of an absolutely pure and stoichiometric MgO, which defects are likely to be created and present in higher concentrations at a temperature of say 1400°C or 1673 K?

We can calculate the Schottky defect concentration as

Electron and hole concentrations are calculated as

In MgO,

  and  

where mo is the mass of free electron and is 9.1×10­31 kg.

At 1673K, Eg = 7.85 eV – (1570*1*10­3 ) eV = 6.28 eV .

Hence, ne = nh = 4.6*1010 cm­3

Now magnesium vacancy concentration can be calculated as

[]
 
 

Hence, at 1400°C, despite high energy of Schottky defect formation, the vacancy concentration will be slightly larger than the electronic carrier concentration due to thermal excitation.