Module 5: Principles of Active Vibration Control
  Lecture 22: Introduction to Active Vibration Control: Organization
 


Three Basic Control Structures for AVC

AVC is implemented broadly using either of the three control systems–


SISO Control

Figure 22.6: SISO control

A typical Classical Control System where G(s) represents the transfer function of a single degree of freedom vibrating system, H(s) the transfer function of a sensor and Gc(s) the transfer function of the controller + actuator. This type of system works well when the vibrating system could be represented as several decoupled SDOF vibrating system.