Figure 4(e) compares the dimensionless temperature profiles at steady state along the centerline
of the cavity obtained from the color schlieren measurements with those reported from measurements. A
reasonably good match among color schlieren measurements of the present work
with laser schlieren and interferometry validates the data analysis procedure.
Figure 5: Comparision of interferometry, monochrome schlieren, and color schlieren applied to convection in a differently heated cavity.
|