Fig. IV.9: Offsets exhibited by first order and second order processes
Note that both natural period of oscillation and damping factor decreased in closed loop response;more the value of controller gain less are the values of natural period of oscillation and damping factor. As a result the closed loop response becomes more oscillatory than its open loop counterpart.
IV.2.4 Effect of integral control action on a process
We shall find closed loop response of first order process under the influence of an “integral only” controller.
![]() |
(IV.31) |
It indicates that the order of the dynamics for the closed loop response is increased when integral control action is used. As a result, the response becomes sluggish.
Following derivation gives an account of the offset shown by first order closed loop process with a PI controller. The final value of the process on unit step change in setpoint is
(IV.32) |
(a) First order process
(b) second order process 