Module 2: Combustion and heat utilization
  Lecture 13: Flame Temperature
 

 

Exercise- 1

Flame temperature with theoretical air

Calculate theoretical maximum adiabatic flame temperature of fuel gas of composition
 when burnt with theoretical air. Assume fuel and air are mixed at 25oC
Consider 1 mole of fuel gas.

POC Amount (kg mole)
CO2 0.968
H2O 1.920
N2 7.52

 

Heat balance:  Reference Temperature = 25oC

Sensible heat in air & fuel +Heat of combustion = Heat in products of combustion 
(1)

Sensible heat of reactants = 0 since they are supplied .

(2)

 

 

This heat of combustion raises the temperature of POC to the flame temperature.
The heat capacity of POC i. e. Cp’

Where nCO2, nN2 and nH2O are moles of CO2, N2, H2O respectively.