where s.t. (note this type of material shows frequency dependent stiffness
The transmissibilities corresponding to the range of nondimensional frequency parameter (0.1 to 10) is shown in the following figure. Note that at high frequency Type I damper performs better than Type II.
Figure 21.2: Transmissibility vs normalized frequency