Example 7.4: Plot the variation of following effective compliance terms against the fibre volume fractions for both Voigt and Reuss approximation..
Solution: The plots of are shown in Figure 7.12 and plots of are shown in Figure 7.13. The Voigt approximation gives lower bound and Reuss approximation gives upper bound for terms. Further, for terms Voigt approximation gives upper bound and Reuss approximation gives lower bound. |