Module Name | Download |
---|---|
noc20_ee09_assigment_1 | noc20_ee09_assigment_1 |
noc20_ee09_assigment_10 | noc20_ee09_assigment_10 |
noc20_ee09_assigment_11 | noc20_ee09_assigment_11 |
noc20_ee09_assigment_12 | noc20_ee09_assigment_12 |
noc20_ee09_assigment_2 | noc20_ee09_assigment_2 |
noc20_ee09_assigment_3 | noc20_ee09_assigment_3 |
noc20_ee09_assigment_4 | noc20_ee09_assigment_4 |
noc20_ee09_assigment_5 | noc20_ee09_assigment_5 |
noc20_ee09_assigment_6 | noc20_ee09_assigment_6 |
noc20_ee09_assigment_7 | noc20_ee09_assigment_7 |
noc20_ee09_assigment_8 | noc20_ee09_assigment_8 |
noc20_ee09_assigment_9 | noc20_ee09_assigment_9 |
Sl.No | Chapter Name | MP4 Download |
---|---|---|
1 | Course contents | Download |
2 | Introduction | Download |
3 | Historical developments | Download |
4 | Power semiconductor devices | Download |
5 | General converter configuration | Download |
6 | Choice of converter configuration: Valve utilization factor | Download |
7 | Choice of converter configuration: Transformer utilization factor | Download |
8 | Converter configuration for pulse number equal to 6 | Download |
9 | Analysis of 6 pulse LCC neglecting inductance | Download |
10 | Analysis of 6 pulse LCC neglecting inductance: Jumps in voltage across a valve | Download |
11 | Analysis of 6 pulse LCC neglecting inductance: Average DC side voltage | Download |
12 | Fourier series: Part 1 | Download |
13 | Fourier series: Part 2 | Download |
14 | Analysis of 6 pulse LCC neglecting inductance: DC side voltage harmonics | Download |
15 | Analysis of 6 pulse LCC neglecting inductance: Fundamental and harmonic components of AC side current | Download |
16 | Definitions: Delay angle, angle of advance, commutation margin angle | Download |
17 | Commutation margin angle in a 6 pulse LCC neglecting inductance: Part 1 | Download |
18 | Commutation margin angle in a 6 pulse LCC neglecting inductance: Part 2 | Download |
19 | Instantaneous power on AC and DC sides in a 6 pulse LCC neglecting inductance | Download |
20 | Average power on AC and DC sides in a 6 pulse LCC neglecting inductance | Download |
21 | 6 pulse LCC with inductance | Download |
22 | 2 and 3 valve conduction mode of 6 pulse LCC | Download |
23 | 2 and 3 valve conduction mode of 6 pulse LCC: DC side voltage harmonics | Download |
24 | 2 and 3 valve conduction mode of 6 pulse LCC: DC side voltage and voltage across a valve | Download |
25 | 2 and 3 valve conduction mode of 6 pulse LCC: Fundamental and harmonic components of AC side current | Download |
26 | Extinction angle | Download |
27 | Extinction angle: Commutation margin angle for normal inverter operation of 6 pulse LCC | Download |
28 | 3 and 4 valve conduction mode of 6 pulse LCC | Download |
29 | Analysis of 3 and 4 valve conduction mode of 6 pulse LCC: Part 1 | Download |
30 | Analysis of 3 and 4 valve conduction mode of 6 pulse LCC: Part 2 | Download |
31 | Analysis of 3 and 4 valve conduction mode of 6 pulse LCC: Part 3 | Download |
32 | 3 valve conduction mode of 6 pulse LCC | Download |
33 | Commutation margin angle | Download |
34 | Normalization | Download |
35 | Characteristics of 6 pulse LCC: Part 1 | Download |
36 | Characteristics of 6 pulse LCC: Part 2 | Download |
37 | Steady state analysis of a general LCC: Part 1 | Download |
38 | Steady state analysis of a general LCC: Part 2 | Download |
39 | Steady state analysis of a general LCC: Application to 6 pulse LCC | Download |
40 | 6 pulse LCC with resistance included on the AC side | Download |
41 | 6 pulse LCC with resistance, inductance and voltage source on the DC side: Part 1 | Download |
42 | 6 pulse LCC with resistance, inductance and voltage source on the DC side: Part 2 | Download |
43 | Power factor | Download |
44 | Capacitor commutated converter: Part 1 | Download |
45 | Capacitor commutated converter: Part 2 | Download |
46 | 12 pulse LCC: Part 1 | Download |
47 | 12 pulse LCC: Part 2 | Download |
48 | Modes of operation of 12 pulse LCC | Download |
49 | Purposes of transformer | Download |
50 | Applications of DC transmission | Download |
51 | Types of DC link: Monopolar | Download |
52 | Types of DC link: Bipolar and homopolar | Download |
53 | DC link control | Download |
54 | DC link control: Control variables | Download |
55 | Considerations that influence selection of control | Download |
56 | Converter control characteristics | Download |
57 | MTDC systens: Applications | Download |
58 | Types of MTDC systems | Download |
59 | Non-characteristic harmonics | Download |
60 | Effect of firing angle errors | Download |
61 | Problems with harmonics | Download |
62 | Single tuned filter | Download |
63 | Design of single tuned filter: Part 1 | Download |
64 | Design of single tuned filter: Part 2 | Download |
65 | Double tuned and damped filters | Download |
66 | Reactive power requirement | Download |
67 | Comparison of AC and DC transmission | Download |
Sl.No | Chapter Name | English |
---|---|---|
1 | Course contents | Download Verified |
2 | Introduction | Download Verified |
3 | Historical developments | Download Verified |
4 | Power semiconductor devices | Download Verified |
5 | General converter configuration | Download Verified |
6 | Choice of converter configuration: Valve utilization factor | Download Verified |
7 | Choice of converter configuration: Transformer utilization factor | Download Verified |
8 | Converter configuration for pulse number equal to 6 | Download Verified |
9 | Analysis of 6 pulse LCC neglecting inductance | Download Verified |
10 | Analysis of 6 pulse LCC neglecting inductance: Jumps in voltage across a valve | Download Verified |
11 | Analysis of 6 pulse LCC neglecting inductance: Average DC side voltage | Download Verified |
12 | Fourier series: Part 1 | Download Verified |
13 | Fourier series: Part 2 | Download Verified |
14 | Analysis of 6 pulse LCC neglecting inductance: DC side voltage harmonics | Download Verified |
15 | Analysis of 6 pulse LCC neglecting inductance: Fundamental and harmonic components of AC side current | Download Verified |
16 | Definitions: Delay angle, angle of advance, commutation margin angle | Download Verified |
17 | Commutation margin angle in a 6 pulse LCC neglecting inductance: Part 1 | Download Verified |
18 | Commutation margin angle in a 6 pulse LCC neglecting inductance: Part 2 | Download Verified |
19 | Instantaneous power on AC and DC sides in a 6 pulse LCC neglecting inductance | Download Verified |
20 | Average power on AC and DC sides in a 6 pulse LCC neglecting inductance | Download Verified |
21 | 6 pulse LCC with inductance | Download Verified |
22 | 2 and 3 valve conduction mode of 6 pulse LCC | Download Verified |
23 | 2 and 3 valve conduction mode of 6 pulse LCC: DC side voltage harmonics | Download Verified |
24 | 2 and 3 valve conduction mode of 6 pulse LCC: DC side voltage and voltage across a valve | Download Verified |
25 | 2 and 3 valve conduction mode of 6 pulse LCC: Fundamental and harmonic components of AC side current | Download Verified |
26 | Extinction angle | Download Verified |
27 | Extinction angle: Commutation margin angle for normal inverter operation of 6 pulse LCC | Download Verified |
28 | 3 and 4 valve conduction mode of 6 pulse LCC | Download Verified |
29 | Analysis of 3 and 4 valve conduction mode of 6 pulse LCC: Part 1 | Download Verified |
30 | Analysis of 3 and 4 valve conduction mode of 6 pulse LCC: Part 2 | Download Verified |
31 | Analysis of 3 and 4 valve conduction mode of 6 pulse LCC: Part 3 | Download Verified |
32 | 3 valve conduction mode of 6 pulse LCC | Download Verified |
33 | Commutation margin angle | Download Verified |
34 | Normalization | Download Verified |
35 | Characteristics of 6 pulse LCC: Part 1 | Download Verified |
36 | Characteristics of 6 pulse LCC: Part 2 | Download Verified |
37 | Steady state analysis of a general LCC: Part 1 | Download Verified |
38 | Steady state analysis of a general LCC: Part 2 | Download Verified |
39 | Steady state analysis of a general LCC: Application to 6 pulse LCC | Download Verified |
40 | 6 pulse LCC with resistance included on the AC side | Download Verified |
41 | 6 pulse LCC with resistance, inductance and voltage source on the DC side: Part 1 | Download Verified |
42 | 6 pulse LCC with resistance, inductance and voltage source on the DC side: Part 2 | Download Verified |
43 | Power factor | Download Verified |
44 | Capacitor commutated converter: Part 1 | Download Verified |
45 | Capacitor commutated converter: Part 2 | Download Verified |
46 | 12 pulse LCC: Part 1 | Download Verified |
47 | 12 pulse LCC: Part 2 | Download Verified |
48 | Modes of operation of 12 pulse LCC | Download Verified |
49 | Purposes of transformer | Download Verified |
50 | Applications of DC transmission | Download Verified |
51 | Types of DC link: Monopolar | Download Verified |
52 | Types of DC link: Bipolar and homopolar | Download Verified |
53 | DC link control | Download Verified |
54 | DC link control: Control variables | Download Verified |
55 | Considerations that influence selection of control | Download Verified |
56 | Converter control characteristics | Download Verified |
57 | MTDC systens: Applications | Download Verified |
58 | Types of MTDC systems | Download Verified |
59 | Non-characteristic harmonics | Download Verified |
60 | Effect of firing angle errors | Download Verified |
61 | Problems with harmonics | Download Verified |
62 | Single tuned filter | Download Verified |
63 | Design of single tuned filter: Part 1 | Download Verified |
64 | Design of single tuned filter: Part 2 | Download Verified |
65 | Double tuned and damped filters | Download Verified |
66 | Reactive power requirement | Download Verified |
67 | Comparison of AC and DC transmission | Download Verified |
Sl.No | Language | Book link |
---|---|---|
1 | English | Not Available |
2 | Bengali | Not Available |
3 | Gujarati | Not Available |
4 | Hindi | Not Available |
5 | Kannada | Not Available |
6 | Malayalam | Not Available |
7 | Marathi | Not Available |
8 | Tamil | Not Available |
9 | Telugu | Not Available |