Dear students myself Devaprasad Kastha welcome you to this introductory course on electrical
machine one. You all know that electrical machines are basically electromechanical energy
conversion devices which convert electrical energy to mechanical energy and vice versa.
More than 90 percent of all electricity generated is by means of conversion from mechanical
energy to electrical energy, and again more than 70 percent of all electricity generated
is finally converted to mechanical form through again this electrical machines; that goes
on to show you the importance of electrical machines in the field of electrical engineering.
Now there are different types of electrical machines that are used, although their basic
operating principles are somewhat similar, they are very different from their point of
view of construction and usage. In this course we will talk about two types of electrical
machines, namely the transformer and the dc machine. This is as I said is an introductory
course, hence does not assume any previous knowledge on the part of the student regarding
the material; however, we do assume some working knowledge on the basic principles of the working
of electrical circuits and basic methodologies for electrical circuit analysis.
The text book for this course are Alexander S. Langsdorf. The name of the book is “Theory
of Alternating Current Machinery.” This is second edition; the publisher is Tata Mcgraw-Hill,
and the year of publication is 1993, this is one text book. The other one is by professor
D. P. Kothari and sir I. J. Nagrath. The name of the book is “Electric Machines.” This
is third edition; the publisher again is Tata Mcgraw-Hill, year of publication is 2004.
Other than these two books we will also have occasion to refer to other text books, but
that I will let you know as and when we use them.
The first electrical machine that we will pick up are transformers. Now as you will
very soon see it is not really a electromechanical energy conversion device. It in fact, converts
the voltage level of the AC supply. So, before we go into the constructional features or
the operating principle of a transformer, I would like to show why a voltage transformation
is required at all. Now the present electrical power generation plants work on the principle
of economy of scale; that means the larger the power plant the cheaper will be the electricity
generated by it, at least that is the belief; however, you can easily understand that such
a large power plant cannot really be located near a dense populated city.
There are many constraints; for example, space, environmental pollution, availability of raw
material, water, and then coal. So, all these constraints usually determine where a power
plant will be located, and it can be very long distance away from the point where the
electricity will be ultimately used, and also all the electricity generated by a large power
plant cannot be used at a single place. So, that brings in the question of transmitting
large amount of electrical power that is in thousands of megawatts over very long distance
more than hundreds of kilometers, and this has to be done efficiently in order to make
the economy work.
Now we will see how the voltage level of transmission affects the efficiency of power transmission.
Let us say there is a load
which needs P amount of power at a voltage of V, and this power is being transmitted
from a generating station which is some L meters away from the load. You can easily
find out the current drawn by the load I; I is given by P by V. Now, the load is connected
to the source using a transmission line; transmission lines are usually designed to operate at a
constant current density J. Therefore, the cross-sectional area of the conductor a will
be equal to I by J. The resistance of the transmission line R, then is given by rho
L by a which is equal to rho L J by I where rho is the resistivity of the transmission
line material, L is the length, and a is of course, the cross sectional area.
So, what is the total power loss in transmission? Power loss P L equal to I square R, but I
is given by P by V; therefore, this is also equal to, but I again itself is given by P
by V. So, we see in order to transmit a given quantity of power P the power loss P L by
P, the percentage power loss P L by P is proportional to L by V. So, larger the voltage V smaller
will be the power loss. So, that says that the power should be transmitted at the maximum
possible voltage. So, how do we determine this voltage?
Now, in order to transmit this power from the generating station to the load we will
need to erect transmission towers, and larger the voltage higher will be the height of the
transmission tower. So, there will be some cost associated with constructing these transmission
towers. So, when we reach a breakeven point that is the cost of erecting those transmission
towers exceeds the power loss that will be saved, that is the voltage which will be chosen
for transmitting a given amount of power, or whatever voltage is permitted by the present
state of technology. Whatever may be the criteria this voltage usually comes to a substantially
large value. Nowadays the maximum transmission voltage
is in excess of 400 kilovolt; however, generating alternating voltage at this voltage level
of 400 kilovolt or even 100 kilovolt is not very convenient, because after all, this power
has to be generated in the confined space of a generator and providing for insulation
in that confined state at that high voltage level is problematic. Therefore, generation
of electrical power will be usually at a much lower voltage in the range of 11 kilovolt
possibly. Similarly when you want to consume this power at the load end; it is not convenient
to use the same 400 kilovolt or 200 kilovolt or whatever is the transmission voltage, because
that is neither convenient from the construction point of view of the load nor is it safe.
Therefore, the load will also like to see the voltage at a much lower level; that brings
into the question that both at the generating end and at the load end you need to change
the voltage level, and this is done using transformers. So, the general construction
will be you have this generating station which will feed a transformer; the transformer will
be connected to the transmission line on the load end. There will be another transformer
which will connect to the load. So, this is the idealistic construction of a transmission
system for electrical power from the generating station to the load; of course, you can understand
that there will be some power loss associated with the transformers themselves.
And since the purpose of this transformer is to raise the transmission voltage level
in order to reduce loss, the transformers themselves should be very efficient; otherwise,
the purpose will be defeated. Fortunately transformers can be constructed to give really
very high efficiency in the large power range; it is not unusual to make transformers with
efficiencies larger than 98 percent, and this scheme works. In fact, it is the possibility
of easy voltage transformation at very high efficiency that has made alternating current
system almost universally acceptable over the direct current transmission system; that
is it.
Now let us see how this voltage transformation can be achieved? The simplest way to do it
is to put a potential divider; that is you put a potential divider, and connect the load
here. Well, it can work only for stepping down the voltage; of course, you can understand
it is not possible to increase the load voltage above the supply voltage, not only that, there
will be continuous power loss in the potential divider resistance. So, this is not very efficient.
If it is an alternating circuit then this resistance can be replaced by an inductive
potential divider. That will solve the problem of power loss, because an inductor in steady
state will not consume any power, but then this circuit is not just an inductive potential
divider; it is something more than that. If you exchange the position of the load and
the source; that is if you supply the power at this point and connect the load here, the
load will see a voltage which is larger than the supply voltage. So, this construction
as we will see is actually called an auto transformer, and we will have occasion to
discuss it in more detail at later point of time. Here unlike a resistive potential divider
the power transfer takes place both conductively through this path and also by magnetic induction
because of flux coupling between the two sections of the windings. This is the principle of
transformer, and since magnetic coupling does not require physical connection between the
windings it is entirely possible to separate this auto transformer arrangement into two
different windings. For example, it will then look like this.
These two windings are magnetically coupled, and power transfer takes place through this
magnetic field. Now this arrangement has some advantage over this; just consider that there
is a short circuit somehow between these two terminals. What will happen? If this side
voltage is much larger than this; for example, this side if it is 11 kV and if this side
is just 400 volts, as soon as there is a short circuit a single short circuit the load will
see the full 11 kilovolt applied across it and will consequently be destroyed probably.
The same fault here; the same fault here will not cause any such catastrophic failure.
In order to have this kind of a catastrophic failure here both end, at both end there should
be a short circuit the possibility of which is far less. So, this construction is preferred
over this construction of a transformer particularly in cases where the voltage levels on two sides
are widely different. This is called the two winding transformer or simply the transformer.
Now that we have mentioned the transformers work on the principle of magnetic coupling
it will be worthwhile to recapitulate whatever we have studied regarding magnetic circuits,
magnetic coupling, induced voltage in the basic electrical technology course once more.
So, what is a magnetic circuit? By magnetic circuit we mean this kind of a construct.
You have a core of some regular shape on which some winding is put. Now if there is no current
flowing into this coil we do not expect any flux lines to be generated in this core; however,
when you switch this source on and a current does flow then magnetic lines of force will
circulate inside this core. The flux density or the magnet field intensity inside the core
will depend on the magnitude of the current i into the number of turns in the coil N.
This quantity multiplication of N and i is called the magneto motive force or MMF, and
this magneto motive force causes a flux to circulate.
So, we can see an analogy with an electrical circuit where the magneto motive force takes
the place of EMF or voltage source in an electrical circuit and the flux which is the effect takes
the place of current which is the effect in a electrical circuit. From this analogy we
call this a magnetic circuit; we will see further analogies later on. But before we
get into how to draw this magnetic circuit let us recapitulate some fundamental laws
regarding magnetic fields.
We all know that if a conductor carries some current i then at a point near the conductor
there will be a magnetic field. A magnetic field can be characterized by a magnetic field
intensity vector H or a magnetic flux density vector B. The relationship between these two
is very simple. B is equal to mu naught mu R H, where mu naught is the permeability of
free space and is given by 4 pi into 10 to the power minus 7; mu R is a dimensionless
quantity. It is called the relative permeability of the material with which the core is made;
for free space mu R is one; for ferromagnetic material it can be in thousands.
Now the magnetic flux density, the incremental magnetic flux density at any point near a
conducting wire due to a small length of the wire d L is given by the Biot-Savart’s law,
which says you can find out the incremental flux density d B; from the formula d B equal
to mu naught mu r by 4 pi into i dL cross r by r cube, where r is the position vector
of the point from the incremental length dL. Please note that the d B is a vector, and
its direction will be determined by the cross product of i dL and r. In this case r is in
this direction, and i dL is in this direction; therefore, the direction of B will be out
of this paper, on the top. The total flux density B at that point due
to length of the wire can be obtained by integral equal to integral over length mu naught mu
R by 4 pi i dL cross r by r cube. While this gives a general formula for determining the
flux density near a conducting wire in practice this integration is difficult to perform except
for very simple structure of the current carrying conductor.
Therefore, for solving magnetic circuits we use a different formula which is the ampere’s
circuital law. This says that the line integral of magnetic flux intensity H over a closed
path is equal to the current total current enclosed. There may be several of them the
total current enclosed; that is integral over a closed path H dot dL equal to the total
current enclosed. This law is very convenient for finding out the flux density and the magnetic
field intensity in magnetic circuits; let us see why.
The structure of a magnetic circuit as we have said consists of a regular core and a
winding. Now when this winding is excited there will be flux line inside the core. Since
the relative permeability of the core is normally much higher than air or free space almost
all the flux lines will be confined inside the core. Also since the total amount of flux
crossing the core at any position of the core is fixed the flux density along this flux
line is constant, and hence the H over this path is constant. Now if we choose the closed
path of the circuital law to be something inside this core we know that H over this
length is constant; therefore, we can find out H from the simple formula that if there
are total N number of conductors carrying current I then the total current enclosed
is N I, and if the length of the mean length of the path to the core is L then H is given
by NI by L. So, in a magnetic circuit finding out the
value of H and hence the value of B which is nothing but mu naught mu R H is relatively
simple. This of course makes the assumption that the leakage flux outside the core is
almost negligible. Now this gives you a method of relating the flux with the MMF in I. That
is the total flux a phi is equal to the flux density B multiplied by the cross-sectional
area of the core A which is then is given by mu naught mu R H is given by N I by L into
A, or this is given by N I divided by mu naught Phi is equal to B into A which is mu naught
mu R; H is N I by L mu naught mu R A.
So, if N I is the MMF then flux phi can be written as phi equal to MMF N I by reluctance
R where the reluctance R of the core is given by L divided by mu naught mu R A. So, if we
extend the analogy that the MMF N I is equivalent to a source of potential, and flux is equivalent
to a current in a magnetic circuit then the quantity reluctance is equivalent to resistance
in an electrical circuit; therefore, a magnetic circuit can be represented by a MMF source
N I which sends flux through a reluctance R.
The corresponding equivalent electrical circuit is a voltage source E sending a current through
a resistance R; that is why this kind of a structure with a core with a winding on it
is referred to as a magnetic circuit because of its similarity with an electrical circuit.
In practice though this magnetic circuit is somewhat more complicated than a electrical
circuit. In a electrical circuit the resistance is normally constant; however, in almost all
practical magnetic circuits the core material is made up of ferromagnetic material.
One property of this ferromagnetic material is that the relationship between the flux
density and H magnetic field intensity is not linear; that is if we plot the flux density
B versus the magnetic field density H. If it was linear then it would have been a straight
line; however, for most material most practical ferromagnetic material it is not so. Initially
it follows a straight line, but as B increases after some point this starts deviating from
a straight line. In fact, B does not increase as fast as H, and beyond some point even if
you keep on increasing H, B practically do not increase.
This is due to the special constructional feature of this magnetic material which are
made up of very tiny molecular level magnetic dipoles; however, almost all ferromagnetic
material exhibits these characteristics which is called the B-H characteristics, and that
B H characteristics has a prominent saturation phenomenon where the relationship between
B and H is nonlinear, and after a critical value of B further increase in H does not
really increase B to a very great extent. Therefore, for ferromagnetic material the
practical operating point that realizes the true potential of the material is somewhere
in this junction in this region where the B H curves starts bending. This is called
the knee point of operation. Because beyond this point even if you put
a large MMF that is H there will not be much increase in the magnetic flux density or the
total magnetic flux circulated; obviously, in this region the relative permeability of
the material which is mu R equal to B divided by mu naught H does not remain constant; therefore,
reluctance of the magnetic core which is given by R equal to L divided by mu naught mu R
A does not remain constant for all values of B. This is what makes analysis of magnetic
circuit somewhat more difficult compared to analysis of a electrical circuit, let us see
why.
A magnetic core need not always be made of a single material. In many cases a magnetic
core in addition to the ferromagnetic core material we will also possibly include an
air gap. Now the relative permeability of the air gap and the magnetic core are very
different. So, how we are going to find given a number of turns and the current flowing
through it; how are we going to find out what is the total flux circulated? In this case
where the magnetic circuit has two different types of material with two different relative
permeability. In an electrical case it would have been simple. This is basically a series
circuit; we could have drawn it for electrical case; we could have drawn it as a MMF source
N I, reluctance of the magnetic path magnetic core R core in series with the reluctance
of the air gap or air. The problem with ferromagnetic material is
that the value of R c is not known at priority, because it depends on the value of the flux
density as we have already seen. The value of R a more or less remains constant, it is
not a function of the flux density it is linear; the B H characteristics of air gap is linear.
Therefore solving this involves is a little more involved, and let us see how we will
solve this kind of a circuit. Although the field intensity may be different the total
flux crossing the core material and the air gap of course same. If we neglect the fringing
effect at the air gap then the flux density in the core and flux density in the air should
also be same. The total MMF N I can be written as flux magnetic field intensity
H c in the core multiplied by the length of the core plus field intensity in the air gap
multiplied by the length of the air gap. But the relationship between intensity in
the air gap and the flux density is constant; therefore, N I equal to H c into L c plus
H is equal to B air by mu naught since mu R for air gap is one into L a, but B a is
equal to B c. Therefore, we can write N I equal to H c L c plus B c by mu naught L,
a or B c equal to mu naught into N I minus H c L c by L a. This is one relationship relating
B c to H c which is linear. The other relationship between B c and H c is given by the B H curve
of the material.
Now we plot them together H c on this axis and B c on y axis. This is the intrinsic B
H characteristics of the material, and the other one given by the circuit which is can
be considered as a magnetic load line. The intersection of these two curves will give
you the operating point H c zero and B c zero. So you see, although solution of a magnetic
circuit like this is somewhat more involved than solving an equivalent electrical circuit,
but it can still be handled in a graphical manner, and this approach is used. At this
point we think that we have discussed sufficiently about magnetic circuit. So, we will move to
a different topic which is the induced voltage in a coil.
Let us say we have a magnetic core, and we are using a coil to set up magnetic flux in
this direction. If the current flowing is into the coil is direct current then this
flux will be a direct flux; however, if the core is excited with alternating current then
the flux will also be alternating. We have seen the relationship between the flux and
the current which is linear if the reluctance of the material can be assumed to be constant.
The question now comes if I put another coil around this leg, what will happen? This has
been studied by Michael Faraday, and the famous law says that there will be a voltage induced
in this coil one, two. The magnitude of the induced voltage e will be proportional to
the rate of change of flux density d phi d t multiplied by the number of turns in the
coil N, and the polarity of the induced voltage will be such that it will try to oppose the
very cause which it is due. Let us look at it a little more carefully what that means.
Let us say this is our coil, and there is a flux phi in the upward direction. This is
a coil with let us say N turns, and there is a flux phi in this direction, and let the
phi be varying in a sinusoidal fashion phi equal to phi max sin omega t. So, by Faraday’s
law the induced voltage e will be such that magnitude e will be proportional to N d phi
d t equal to N omega phi max cos omega t, and the direction of the polarity of the induced
voltage will be such that it will tend to oppose the very cause which it is due; what
is the cause that the changing of the flux. Now let us see at t equal to 0 the flux was
0, and as time progresses t becomes positive; this flux tries to increase.
So, in order to oppose that cause, what the induced voltage will try to do? If you close
this switch this induced voltage E will send a current through this loop which will tend
to cancel this current which will tend to cancel this flux; therefore, the circulating
current will be generating a flux which will be in the opposite direction. So, what will
be the direction of that current which we can cancel this flux; obviously, the current
will be in this direction. Therefore, this coil with this kind of a flux can be replaced
by an emf source E where the terminal 2 at time 0 will be positive, and the terminal
1 at time 0 will be negative, and the potential E 21 in that case will be given by N omega
phi max cos omega t. So, if we want to find out the rms value, then E 21 equal to omega
is given by 2 pi f into N phi max divided by root 2.
Or the induced voltage E equal to 2 pi by root 2 is 4.44 f phi max N. So, this is the
formula of induced rms voltage in a coil with number of turns N which links a alternating
flux phi. Generally alternating quantities in ac circuit analysis are represented by
phasors; therefore, if we draw the phasors and take the flux phasor to be the reference
phasor then the induced voltage E will be leading it by an angle 90 degree. Here I would
like to bring to your attention some of the conventions that are used by the authors of
different books. The quantity that we have been calling induced voltage in fact by many
authors is called the counter induced voltage, because here we have got this e by simply
saying e equal to N d phi d t. And we have incorporated the last part of
the Faraday’s law that is it opposes the very cause which it is due by taking its proper
polarity. This many authors call the counter induced voltage. The actual Faraday’s law
says e equal to minus N d phi d t. So, in our case this e will be opposing the supply
voltage in the case where e is taken with a negative sign. This is called the induced
voltage; therefore, in our case the KVL of the coil will be written as V equal to e;
in this case the KVL will be written as V plus e equal to 0, that is the only difference.
In fact, if there is no scope of confusion then we will keep calling this as the induced
voltage although many authors in some text books will be calling it the counter induced
voltage.
Auto Scroll Hide


New Assignments
Module NameDownload
Assignment-10question and solutionAssignment-10question and solution
Assignment-11question and solutionAssignment-11question and solution
Assignment-12question and solutionAssignment-12question and solution
Assignment-1question and solutionAssignment-1question and solution
Assignment-2question and solutionAssignment-2question and solution
Assignment-3question and solutionAssignment-3question and solution
Assignment-4question and solutionAssignment-4question and solution
Assignment-5question and solutionAssignment-5question and solution
Assignment-6question and solutionAssignment-6question and solution
Assignment-7question and solutionAssignment-7question and solution
Assignment-8question and solutionAssignment-8question and solution
Assignment-9question and solutionAssignment-9question and solution





Sl.No Language Book link
1EnglishDownload
2BengaliNot Available
3GujaratiDownload
4HindiDownload
5KannadaDownload
6MalayalamNot Available
7MarathiNot Available
8TamilNot Available
9TeluguNot Available